Chlory 100ppm 200ppm 500ppm Hypochlorous Acid (HOCL) Generator – PEM Electrolysis Disinfectant Syste

Chlory 100ppm 200ppm 500ppm Hypochlorous Acid (HOCL) Generator – PEM Electrolysis Disinfectant Syste

Core Features

  • Adjustable HOCL concentration: 100ppm, 200ppm, 500ppm
  • PEM membrane electrolysis, pure HOCL output, no harmful by-products
  • pH 4.5–6.5, ORP 1000–1200mV, high-efficiency disinfection
  • Automatic PLC control with LCD touch screen
  • Real-time monitoring of concentration, pH, current and temperature
  • Safe, non-toxic, non-irritating, residue-free and eco-friendly
  • CE and ISO certified, suitable for global markets
Send Email
Product Introduction

Chlory hypochlorous acid generator adopts advanced PEM electrolysis technology to produce stable, pure hypochlorous acid anolyte with adjustable concentrations of 100ppm, 200ppm and 500ppm. It is widely used in medical disinfection, food processing, animal husbandry, public space and water treatment.

Onsite HOCL Generation System Flow Chart

Working Principle

The system electrolyzes dilute salt water through a PEM electrolytic cell. Under the separation of cation exchange membrane, the anode generates high-purity hypochlorous acid solution, while the cathode produces alkaline water. Only salt, water and electricity are needed for on-site disinfectant production, with low cost and stable performance.

PEM electrolytic cell Working Principle

Technical Specifications

Item Parameter
HOCL Concentration 100ppm, 200ppm, 500ppm adjustable
pH Value 4.5 – 6.5
ORP 1000 – 1200mV
Power Supply AC220V/380V 50/60Hz
Certification CE, ISO

Model List

Model BH-H BH-M BH-E BH-T BH-K
Feature Household
Pet
Clinic
Common type Medical grade
Strong HOCL
Three Outputs
Disinfectants
Top Grade
For Medicine
Surface disinfection
Water disinfection
Input Tap Water
Kitchen SALT
ELECTRICITY
RO WATER
99.5% NACI
ELECTRICITY
RO WATER
Normal Salt
ELECTRICITY
Tap Water
*SALT*
ELECTRICITY
CLEAN WATER
Special Salt
ELECTRICITY
Output HOCL
Alkaline
800ml/time
HOCL
Alkaline NAOH
50L-2000L/H
HOCL
Sodium Hypo
Alkaline NaOH
50L-2000L/H
Only Pure HOCL
Water
50L-2000L/H
Only HOCL water
50L-2000L/H
HOCL Concentration 20-100ppm 20-500ppm 20-2000ppm 100-300ppm 15000ppm
pH adjustable 2-6.5 4.5-6.5 4.5-6.5
>850 >800 >900 >1000 >900
Shelflife 6 months 12 months 12 months 12 months 15 months
PLC Auto Control

Grade and application comparison table

Category Pharmaceutical Grade Medical Grade Common Grade
Concentration (Max) 0-200 ppm, 0-500 ppm, 0-1500 ppm 0-2000 ppm 0-500 ppm
Raw Material Self-Made Salt Salt
Applications Wound, skin, nose, foot, oral, burns, scalds, women's cleaning, epidemic prevention and control, disinfection Medical equipment disinfection, surgery, hospital environment, cosmetics, face cleaning Poultry farm, planting, food/seafood processing, pet disinfection, room cleaning, surface disinfection
Product Pharmaceutical Grade Hyprochlorous Acid Skin Spray BRIOTECH PURE HYPOCHLOROUS PURE SANITY  TOPICAL SKIN AND SURFACE SPRAY

Machine Datasheet:

Dimensions

1000X750X1350mm

Land Size (Area)

3000X3000X2500mm

HOCL Concentration

50-500ppm

500-1500ppm

2000-15000ppm

Production Capacity

50L/H -1000L/H

Natural Acidic (Range)

pH4.5 ~7

Total Power Consumption

1KW-3KW

Electricity Supply

AC 220V /50 -60 Hz

AC 380V /50 -60 Hz

Power Distribution Req.

≥ 3000W

Main features for HCIO acid water Generator,

1-Manual Full Automatic Working, only 1 person required.

2- LED/LCE touch Screen operation, remote control by app on iPHONE/Android

3- Real time online display HOCI Concentration(ppm), pH,Electrolytic current,Temperature 

4- Warning and Alarm when problem occured

5- Continuous produing the disinfectant up to 24hours/day



Applications

  • Medical & hospital: equipment, environment, wound disinfection
  • Food & beverage: processing, cleaning, fresh-keeping
  • Livestock & poultry breeding: farm disinfection, air spray
  • Public places: hotel, school, office, vehicle disinfection
  • Water treatment: drinking water, circulating water disinfection
  • Daily & pet: household cleaning, pet care

Why Choose Chlory HOCL Generator?

  • Stable PEM core technology, long service life
  • On-site production, reduce storage and transportation cost
  • Intelligent control, 24-hour unattended operation
  • Multiple safety protections and alarm system
  • Customizable capacity and concentration for different demands

Frequently Asked Questions

Q: What materials are needed to run the machine?

A: Only food grade or industrial salt, clean water and electricity are required.

Q: Can the concentration be adjusted freely?

A: Yes, the machine supports stable output of 100ppm, 200ppm and 500ppm hypochlorous acid.

Q: Is it suitable for food and medical use?

A: Yes, our HOCL generator meets food safety and medical disinfection standards.

1770ppm Hypochlorous Acid

Send Inquiry

You Might Also Like

  • Anolyte HOCL Generator 500ppm 800ppm 1000ppm

  • Medical Neutral Anolyte HOCl Generator

  • Food grade Anolyte HOCL Generator

  • Medical grade Neutral Anolyte HOCL Generator

  • Seawater Electrochlorination System

  • offshore electrolytic seawater chlorine system

  • Small Sodium Hypochlorite Generator

  • Medium and large sodium hypochlorite generator

  • Spectral Efficient Sterilization Pure HOCL Hypochl

  • 15% sodium hypochlorite plant

  • chlorine dioxide generator(Chlorate)

  • electrolysis chlorine dioxide generator

  • on site chlorine gas generator

  • MESH Electrolysis Cell: Seawater Electrochlorination for On-Site Sodium Hypochlorite Production

  • High Purity Water Treatment System | Custom Industrial Purification Solution

  • Constant Pressure Water Supply Device

  • Chemical Dosing System

  • Pickling Wastewater Treatment

  • 32% Hydrochloric Acid producttion line Hydrochloric Acid plant